file://, http://localhost or HTTPS.
Connection disconnected
On connect, the page reads the firmware version, the work mode, the antenna sequence and the output power. Nothing is written until you press a Write/Set button.
Work mode (function ID)
Background traffic
In autonomous mode the reader may keep sending tag data. The page ignores it and matches only replies to its own commands.
Antennas not read yet
| Antenna | Enabled | Inventory rounds | Output power (dBm) |
|---|
Advanced
The antenna sequence is written with 0x8A as Ant1,r1,Ant2,r2,Ant3,r3,Ant4,r4,interval,0, the same as the vendor tool. A disabled antenna gets 0 rounds, which means "not used for inventory". It is read back with 0x8F.
Output power is written with 0x76 (saved in flash, so it survives a power cycle). The page sends as many bytes as 0x77 returned: 1 for all antennas, or 4 or 8 for one value per antenna. Ports 5–8 are written back unchanged.
Every write is permanent: power is written with 0x76 (saved), and the sequence and mode are kept by the reader's firmware. "Reset & check saved" reboots the reader and compares the values read afterwards, which shows they survive a restart.